HARDWARE MANUAL8:20 AM 04-10-00QZ. ABC1DEF23GHI4JKL MNO56PRS7TUV WXY89-SP0INOUTCLEARALPHAENTERBACKSPACEData Collection Terminal
104. Ports and connectionsAcroprint Data Collection Terminal setup instructionsConfiguring procedure for entering the DATE & TIME:Swipe the Config
11(For RS485 terminals only)Select option 1 for RS485 <press ENTER>Select the baud rate 0 for 1200, 1 for 2400, 2 for 4800, 3 for 9600and 4 for
12Select TRANSACTION TIME OUT <press ENTER>(This controls how long the terminal will restrict between badgeswipes. Example: You want to keep you
13Ethernet portThe Ethernet port is located on the lower left corner of theterminal. It is a 10 position 8-pin female port which will accept amale 10B
14RS-232 Serial portThe RS-232 serial port is locatedon the lower left corner of theterminal. It is a 6 position 4-pinfemale port which will accept am
15RS-232 Serial printer cablesThe terminal serial port is used for connection to a serial printer.Printers, such as the serial printer shown on page 2
16Local Area Network: RS-485 serial portThe RS-485 serial port is located on the lower left corner of theterminal. It is a 6 position 4-pin female por
17Junction Box Daisy Chain Wiring DiagramRS-485 Serial cablesTo terminal(short as possible)To anotherJunction BoxJunction BoxTo serial port onhost c
18Modem portTerminals which are equipped with a MODEM port, will nothave an RS-485 port. The MODEM port, when installed,physically replaces the RS-485
19Modem cablesThe cabling for modem operation is typically very simple. Themodular connection uses the two inner wires of the RJ-11 jack fortip and
2FCC Warning:Note: This equipment has been tested and found to comply with the limits for aClass A digital device, pursuant to Part 15 of the FCC rule
20Wand portThe Wand port is located on the lower left corner of the terminal.It is a 6-pin DIN port which will accept a circular DIN connector.The Wan
21Wand and Y-CableDisconnect power to the terminal before connecting the Bar CodeWand. The wand is capable of reading bar code stripes by passingit di
22Parallel portThe parallel port is located on the right side of the Acroprint DataCollection Terminal. It is a 25 pin female port which will accept a
23Parallel cableThe parallel port is typically used for connection to a parallelprinter. Shown below is a parallel interface cable. Since this is thes
24Fingerprint Scanner Kit 25-0124-000Factory Installed OnlyBar Code Wand 74-0106-002and HolderExternal Visible 74-0111-
25External Relay Box 120 V 01-0121-000 240 V 01-0121-002External Buzzer 01-0122-000De
26Description/Illustration Part NumberStandard Modular Cable length - 7 feet 72-0146-000
27Description/Illustration Part NumberDB-9 RS-232 Host Cable AssemblyIncludes DB-9 (RS-232/host) to RJ-11 femaleadaptor and Standard Modular Cable.
5640 Departure DriveRaleigh, NC 27616919.872.5800www.acroprint.comP/N 06-0262-000 Rev. B
3Table of Contents1. Introduction ... 4Basic hardware and variations ...
4Basic hardware and variationsThe electronic hardware is a new, versatile platform designed foruse with various applications. This manual describes, i
5General specificationsA. Enclosure: 8.7 in. (23 cm) wide x 6.1 in. (16 cm) tall x 2.3in. (6 cm) deep. Clamshell construction of 0.125 in. (3mm) thi
62. SetupSite requirementsThe terminal can be installed in any normal office or controlledfactory environment. However, do not use the terminal under
7MountingUnscrew the access door. With the door off, the main unit can beslid upward and removed from the mounting bracket. The bracketcan be used for
83. Operator interfaceADCT KeypadThe terminal has 16 keys for entering alphabetical and numericdata as illustrated below.QZ.1ABC2DEF3GHI4JKL5MNO6PRS7T
9Optionally, the terminal can also have an internal bar code reader.The card is swiped through in the same fashion, but the Bar Codeshould be on the l
Comments to this Manuals